联系我们

  • 如果您有任何问题,请与我们联系,我们将为您解答
  • 电子邮件:David@tmaxcn.com
  • 电子邮件:Davidtmaxcn@gmail.com
  • 添加:中国福建省厦门市海沧区信阳新昌路39号(内地)
integral-dry-room
  • 积分干燥的室内锂电池整体干燥室

    锂电池整体干燥室1.1。每个部分的净化要求:除湿区域区域(㎡)高度(m)体积(㎥)温度(℃)温度(℃)露点(℃)露点(℃)干燥室18 2.1 37.8 25±3≤-40 3 1.2现场要求1.用户提供根据需要,水,电和空气源到单位连接。用户负责对除湿单元的分配柜,天花板空调单元,制冷单元和水泵的主要配电。自来水连接到设备的化妆点,管道(供应空气,排气,返回空气,冷却的冷却水)连接到除湿空调单元和水冷杯的界面。2.用户负责生产设备的水泥基础。2.除湿和温度控制设备列表:2.1区域设备规格列表NO。设备名称供应空气量(M³/ h)单位型号数量。面积使用AHU-1旋转除湿器单元3700 TMAX-3700SCH 1干燥室3.选择设计计算基础:3.1。为夏季用户新空气的设计参数:为了提高系统的稳定性,户外设计参数被视为不良工作条件的参数,干灯泡温度为35℃,相对湿灯泡温度为75%,绝对水分含量为27g / kg; 3.2. System load: light labor intensity produces heat (80-100w/h. person); the comprehensive heat load of the enclosure structure is calculated at 60-110 w/m2 according to the system layout and indoor heat source, with a height correction factor of 2%, equipment The heat load is calculated by 10%-20% of the installed power according to the type; 3.3. Humidity production: when the temperature is 23℃, the humidity production of personnel with light labor intensity is (80-100g/h.person); the ventilation and humidity load of the air-conditioned room is calculated according to the air-conditioning room's 0.1-0.2 air exchange permeability; return air The moisture penetration load is calculated based on the return air volume 1%-3% of the ventilation penetration volume; the ventilation moisture load of the low-humidity dry room is calculated based on the moisture production volume of 2-5g/m2 in the air-conditioned room; 3.4. System air volume: fresh air volume (20-50m3/h. person) and maintaining positive pressure in the room require 5-10 Pa in the drying room; ensure the humidity gradient of the drying system. 4. Unit selection parameter table and system flow chart: 4.1 air conditioning system selection design calculation table scheme: 1. Main equipment type selection design calculation table: (see the description of technical proposal for design basis) No. Regional classification Constant temperature and humidity area 0 Dehumidification unit no AHU-1 1 Name of workshop Drying room 2 Area (M2) 18 3 Ceiling height (m) 2.1 4 Volume (M3) 37.8 5 Temperature and humidity requirements T≤25℃ dew point≤-40℃ 6 Infiltration load of ventilation system (g) 261 7 Enclosure heat load of drying room (W) 3102 8 Design air volume 3700 9 Equipment model JD-3700SCH 10 Design ventilation rate 97.9 11 Design dehumidification capacity (g / h) 261 12 Design heat removal (W) 3102 13 Supply air temperature and dew point 13℃ 14 Air volume CMH Fresh air volume (CMH) 600 Dehumidification air volume of runner 4200 Regeneration air volume (CMH) 500 Supply air volume (CMH) 3700 15 Equipment energy consumption KW   Regenerative heating power (kw) 25 Regeneration fan power (kw) 0.75 Treatment fan power (kw) 3 Motor power of runner drive (kw) 0.13 Total power in summer (kw) 29 16 Cooling load (kw) 41.7 4.2. System flow chart: AHU-1 selects the TMAX-3700SCH system flow chart of the runner dehumidification unit: Note: The runner dehumidification unit is composed of: primary filter section, front stage cooling section, runner dehumidification section, rear cooling section, blower section, regeneration system, control system and refrigeration system. 6. Parts list 6.1. List of main components of the rotary dehumidification unit: Unit parts Material introduction Brand Specification Imported dehumidification runner Adopting Swedish PROFLUTE and American high-quality silica gel molecular sieve or molecular sieve composite runner; the runner has a hygroscopic agent sizing rate of up to 82%, strong moisture absorption capacity in a low temperature and low humidity environment, high temperature resistance strength, and long service life. custom made Front runner silica gel / rear runner silica gel molecular sieve Unit box, frame Adopting the internationally popular modular anti-cold bridge design, high-quality double-layer color steel plate filled with polyurethane one-time foaming and shaping. Aluminum alloy profile frame, beautiful appearance, compact, excellent temperature and humidity insulation effect, no condensation. Yizhong Aluminum Box board inner and outer board 0.5mm color steel plate / box board insulation layer 30mm polyurethane Surface cooler The use of seamless copper tubes to expand and connect the clear water film corrugated aluminum fins has high heat exchange efficiency, low air resistance, and durable and reliable use. TMAX custom watch cooler (a set of fresh air/medium/rear cooler) 15.88 copper pipe*0.5mm Regenerative electric heating tube U-shaped winding sheet stainless steel electric heating rod TMAX 2KW input power filter It can be washed repeatedly and has a long service life. One use one preparation TMAX Primary effect filter plate type G4/medium effect bag type F6 Centrifugal fan Centrifugal fan, high efficiency, low vibration, low noise, stable and reliable performance, insulation class F, protection class IP54. With overheat protection device Zhaoqing Detong or equivalent 6-35 series Runner gear motor Accurate gear engagement, no noise, long service life, with temperature control protection device. Taiwan Dongli or equivalent 5IK series Runner chain Automatic deviation correction, automatic adjustment of tension TMAX / Electrical control The electric control adopts the original Siemens Schneider Electric. The system is equipped with multiple protections such as regenerative fan, runner motor, interlocking protection of runner stall and regenerative heating, and regenerative heating over-temperature protection; the cable is selected from the Jinlongyu brand. Integrated control, measurement, signal, protection, adjustment and other functions. Kunlun Coast/Siemens S7-200CN PLC/MCGS color display/3TB/F Siemens contactor/IC65 Schneider air switch Internal structure Cold rolled plate baking paint/spraying process production, corrosion resistance, aging resistance /Schneider 2mm galvanized steel sheet baking paint Bottom surface water receiving device 304 stainless steel plate TMAX 2mm stainless steel Water retaining device Low resistance, light weight, corrosion resistance, aging resistance TMAX 100mm hydrophobic wet curtain Runner seal The regeneration heating adopts VITRON high temperature resistant silicon fluorine rubber, and the circular arc seal of the runner adopts silicon rubber wear-resistant seal. The pressure difference between the treatment zone and the regeneration zone can reach 1200Pa to ensure the tightness. TMAX Red silicone sealing strip (12CMX2.3MM) Unit chassis 14/6 channel steel welding, two asphalt paint spraying process TMAX 14 / 6 channel steel 1. We supply machines with battery technology support. 2. We supply full set of lithium battery equipment for lab research, pilot scale research and production line. 1 Standard exported package: Internal anticollision protection, external export wooden box packaging. 2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way. 3 Responsible for the damage during the shipping process, will change the damage part for you for free.

进入页面